Description
The ADC150 is a Modulating Fan and Damper Control used with gas fireplaces where it monitors and maintains a constant draft in a chimney. It is used with model RS fans.
It monitors the draft in a chimney system via a connection to a pressure transducer (XTP) attached to the chimney, and maintains the draft by modulating the fan speed.
Features
- 0-10VDC control signal for EDrive and 10-120VAC for variable speed
- Integrated safety system with adjustable shut down time
- Integrated damper relay that works with an EcoDamper.
- End-switches in an EcoDamper actuator can be wired to the ADC150
- Post purge function (180 sec) to evacuate residual flue gases after fireplace shuts down.
Specifications
| Power Supply | 1 x 120VAC |
| Amperage | 6.3A |
| Control Mode | Continuous or Intermittent |
| Control Signals | 0-10 VAC (for VFD) and 120/240 VAC (for direct connect) |
| Range Of Operation | 0-0.6 inWC / 0-150 Pa |
| Tolerance | 0.01 inW (3 Pa) +/- 10% |
| Output | 10-120VAC / 0-10VDC |
| Control Relays | (6) Max 120VAC/8A |
| EMC Standard | Emission: EN50 081-1, Immunity: EN50 081-2 |
| Insulation Class | NEMA 1 (IP 20) |
| Warranty | 2-Year Factory Warranty |